Signals & Systems India Private Limited
In order to implement a 100 % stator earth fault protection based on subharmonic injection, a 20Hz voltage is injected into the generator star point. The 20-Hz generator SGEN-1001 is used in combination with the Band Pass Filter SBPF-1001 in the Stator Earth fault protection. The injection can be performed by connecting the SGEN-1001 and the SBPF-1001 to the load resistor of an earthing or neutral transformer. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. From the driving voltage and the fault current, the protective relay determines the fault resistance.
-
T2000 -
HT Italia Srl
T2000 is a professional clamps specially developed to evaluate resistance of earth rods with no need to disconnect any part of the system (STAKELESS METHOD)
-
MFT5010 -
Summit
It can be used to test insulation resistance, continuity, loop impedance and RCCB, earth resistance tester, five major test requirement in the electrical testing industry. Phase indicator. Can check a wide range of 3-Phase Power source from 110V to 600V
-
Weshine Electric Manufacturing Co., Ltd
UT520 series can perform precise 3-wire and simple 2-wire earth resistance measurement for power and electrical systems, lightning protection equipment, and ground system of all electrical equipment.
-
Axi'An Beicheng Electronics Co., LTD.
Electronic Power Testers by RuoShui; HART process calibrators, process calibrators, digital earth resistance tester, insulation resistance tester, SMD resistor, digital capacitance inductance meter, LCR meters, surface resistance meter, and more
-
AMPI-520 -
Amperis sl
The AMPI-520 digital meter is designed to measure impedance in short-circuit loops without tripping the differential protection, it also measures the protection tare, earth resistance, continuity and phase sequence check.
-
SA-2000 -
BC Group International Inc.
The BC Biomedical SA2000 Features: AAMI Load Earth / Ground Lead Resistance Earth/Ground Leakage Current Chassis Leakage True RMS Measurements 85 to 265 VAC Operation.
-
Mors Smitt Group
All countries in the world have special regulations for testing and approvals of low voltage installations. In many countries these regulations are prescribing installers, inspectors etc. to check the electrical installation periodically. Prescribed tests that need to be performed are:RCD testInsulation resistance testEarth loop impedance testEarth loop resistance test (Rs-test)Earth resistance test
-
Beha-Amprobe
Offers two models that verify the safety of electrical installations in residential, commercial and industrial applications. Has been developed to carry out the following safety measurements of electrical installations in accordance with EN 61557 and DIN VDE 0100: Insulation resistance, RCD tests, Low Ohm resistance, Earth ground resistance, Loop impedance, Phase sequence.
-
Premier Electrosystems
The typical use of high voltage testing is to confirm performance. The high voltage tests are included in type and routine tests to meet the required IS standards, quality and reliability. Some of them are insulation resistance tests, dielectric type tests, lightning and switching impulse tests, partial discharge measurement, etc. Premier's high voltage tester checks the insulation between line to earth, neutral to earth, primary to earth, secondary to earth and between primary & secondary.
-
Fluke 1621 GEO -
Iconic Engineering Limited
The Fluke 1621 is an user-manageable-to-use earth showground tester. For arena resistance psychoanalysis, 1621 is the first pedigree of excuse in detecting honorable sports ground intimates. The unit features basic arena testing methods including 3-pole Fall-of-Potential as accurately as 2-pole sports arena resistance tests.
-
SURE Engineering cc
The SURETECH Motor Insulation Monitor measures insulation resistance to earth of electric motors when themotor stops. Motors running from mains (380 / 220V) and higher voltages up to 6.6kV can have their insulationcontinuously monitored.
-
COMBI519 -
HT Italia Srl
COMBI519 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
COMBI521 -
HT Italia Srl
COMBI521 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
EASYTEST -
HT Italia Srl
EASYTEST carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.